CADEANCO

bar1.jpg (2136 bytes)

Rear Panel Interfaces

[Click on a thumbnail to view full image.]

The Strain Bridge Monitor can be fitted with one of four interfaces.  These take the form of interchangeable rear panels fitted to the instrument case and all have identical ribbon cable connections to the control circuit board.  This enables the user to select an interface designed for the particular transducer to be monitored.  Each interface is composed of a plastic backing panel with a polycarbonate label featuring indelible legends and interface identification.

 

hic4.gif (28038 bytes)

HIC INTERFACE

Designed to accept the CSIRO Hollow Inclusion Stress Cell.   The interface has a 15-way screw terminal connector, 12 adjustable trimpot access screws, a 'BALANCE' select switch and charger input socket.

 

 

mtr4.gif (27713 bytes)

 

MTR INTERFACE

Designed to suit both the CSIRO Yoke Cell and CSIRO Hollow Inclusion Cell installed in permanent monitoring applications.  The panel has a 25 pin D-Connector input plug for each cell type, a temperature monitor switch for Yoke cells and a charger input socket.

 

std1.gif (28259 bytes)

 

STD INTERFACE

Designed as a general interface to accept instrumentation using strain gauge measurement techniques.  The panel has two 25 pin D-Connector input plugs to accept either 12 x Quarter Bridge or 12 x Half Bridge circuits in addition to a charger input socket.

fbc1.gif (22846 bytes)

 

FBC INTERFACE

Designed to accept 12 Full Bridge input circuits via two 25 pin D-Connectors.  These plugs accept input Channels 1-6 and 7-12 respectively and the panel also has a charger input socket.